Gas Testing | ||||
Producers of insulated glass units who have passed the EN1279 parts 2 & 3 for gas filled units are required to test gas concentration levels on a regular basis to maintain their certification, ensure continued consistency of quality.
| ||||
![]() | The latest addition to the Inagas range of testing equiptment has been designed to give accurate analysis of the gas concentration in insulated glass at a realistic price. The testOxy 2 instrument is easy to use and powered by maintenance free batteries which can be recharged using the provided charger. | |||
![]() | ![]() | ![]() | ||
The testing is done by simply inserting the probe into the sealed unit and pressing the start button. The led display starts by showing the inagas logo which indicates the the warm up and calibration sequence has started. The screen will then display 00 and is ready to take gas sample, the result is then shown as a percentage of gas in the IG unit
The TestOxy2 can be used with all types of gas, Argon, Krypton, Xennon and mixed gas sample, enabling the user to comply with the testing requirements of EN1279 | ||||